Committed to quality
and global standards.
A hydrogen product is an electrolyser, a battery, a pressure vessel and a drinking surface at once. Our quality system is built around that reality — incoming inspection, in-process checks, ageing, and concentration verification before anything is packed.
- Management system
- ISO 9001
- Electrical safety
- CE — LVD
- EMC
- CE — EMC
- Materials
- RoHS
- Performance
- H₂analytics laboratory report
On file.
Performance verification
Hydrogen concentration is measured with laboratory analysis and reported in ppb, at defined cycle times. ORP readings are not used as a concentration proxy — the two are not the same measurement.
Test reports and certificate copies are available to distributors and brand owners on request. Please include the model and the destination market.
Four gates before
the carton.
Incoming
Membranes, cells, batteries and housings checked against specification on arrival.
In-process
Assembly checks at the cell, seal and electronics stages, with recorded pass criteria.
Ageing
Run-in and ageing tests to catch early failures before final assembly is closed.
Pre-shipment
Function, concentration, pressure and packing inspection on sampled units.
The tests we
actually run.
Concentration
Dissolved hydrogen measured in ppb at the published cycle times for each model.
Ageing & endurance
Extended run testing on cells and complete units, with performance recorded over time.
Environmental
High and low temperature chamber testing on electronics and finished units.
Pressure & sealing
Chamber pressure and leak checks on bottle platforms before packing.
Need the paperwork
for your market?
Tell us the model and the destination. We will send the relevant certificates, reports and declarations for review.